Overview
The Omnia8 (8 zones) and Omnia4 (4 zones) burglar control panels are
completely programmable. The operating principles of these control panels
are identical, therefore, the instructions in this manual are valid for both
systems.
Omnia8 and
Omnia4
This system has a Main Unit with a built-in communicator and one keypad.
It and can control up to 16 remote devices (key readers and keypads). A
maximum of 8 keypads can be connected ----including the one supplied.
The NormaVox2 voice board enhances the system even further by provid-
ing Voice call management.
Keypads and key readers can be connected to the control panel by a four-
wire parallel bus.
Communicator The Communicator can manage 8 telephone numbers for central station
communication and teleservice. A Customer code, and a communication
protocol can be assigned to each central station telephone number.
The Event codes (e.g. Arm, Disarm, Alarm, Fault Warning) will be sent to
the programmed central station telephone numbers. It is possible to assign
a 2 digit code to each event.
Voice messages The optional "NormaVOX2 Voice Recorder" can record and send up to 8
voice messages to 1 or more of the 8 programmed Voice call telephone
numbers.
Teleservice and
remote
monitoring
Teleservice and remote monitoring of the control panel can be done from a
Personal Computer with the OmniaMod modem and management soft-
ware.
Programming The control panel can be programmed from:
Ø any keypad;
Ø on-site Personal Computer connected to the RS232 interface on the main
board;
Ø remote Personal Computer connected to the Main Unit through the Om-
niaMOD modem via telephone line.
8 Security System Control Panels Omnia8/Omnia4