Keypads Keypads should be installed in places where access to the following op-
tions is required: Programming, Disarm by Duress code, Zone Bypass, Re-
set Alarm Memory and Enable Teleservice. Key readers do not provide
the aforesaid options.
Keypad mounting (refer also to the illustration on page 13)
1. Unfasten the screws 17 and remove the frontplate.
2. Push the tab 19 upwards to release the PCB.
3. Pass the cables though the cable hole 26.
4. Check for cable conduits and water pipes before drilling any holes. Use the
holes 27 ( 4 mm) on the backplate as a drill pattern.
5. Fit the backplate to the wall.
6. Replace the PCB.
7. Make the connections on the terminal board 23 and assign device ad-
dresses by means of the dipswitches 22.
8. Replace the frontplate and fasten the screws 17.
Key readers Install key readers as per light switches and plug sockets. Install in places
where access to system arming/disarming only is required.
+
Make the connections on the terminal board 30 and assign addresses by
means of the dipswitches 31 before mounting the key readers.
Figure 8 Transformer installation
18 Security System Control Panels Omnia8/Omnia4