Times
The Entry time, Exit time and Arming delay time of each partition can be
programmed separately in this page.
The Control panel can manage up to 4 partitions.
The partition parameters are as follows.
no. This is the non-modifiable partition identifier number (1 ...4) which will be
used instead of the partition description (refer to following paragraph).
Description This is a modifiable field for the partition name (maximum 16 characters).
The name will allow proper identification of the partition and will be used in
other parts of the program, and in the Event Buffer.
Entry time This setting determines the delay that will be generated by violation of a
zone with Entry Time programming. Entry Time will be signalled by:
Ø activation of the corresponding partition outputs (with Entry Time program-
ming);
Ø an audible signal (fast beep) on the enabled keypads of the partition of the
violated zone.
Exit time Violation of an armed zone with Exit Time programming will not generate
an alarm during the programmed delay. The delay will start when the parti-
tion is armed, and will be signalled by:
Ø activation of the corresponding outputs (with Exit time programming);
Ø an audible signal (slow beep) on the enabled keypads of the partition of
the violated zone.
Arming delay
time
The Arming delay time must be programmed in minutes. An output must
be programmed for the Arming delay signal (in order to signal the elaps-
ing Arming delay time).
Example
The control panel will start signalling at 17.30 and will continue until 17.45
if:
----the Timer is programmed to arm the partition at 17.45
----the partition is programmed with a 15 minute Arming delay time
----an output, assigned to the partition, is programmed with Arming delay
time.
Auto arming can be delayed by 30 minute overtime requests ----valid until
24.00 (refer to "Timer" paragraph).
Arming delay: 0 through 240 minutes with steps of 1 minute
0 minutes = No Arming delay
Patrol Time This setting determines the time between disarming of partitions ----by a
Patrol Code PIN, and rearming. Patrol Time: 0 through 99 minutes. The
programmed time will be the same for all partitions.
46 Security System Control Panels Omnia8/4