Ø Courtesy lamp (during Exit Time): connect a relay coil to a power supply
terminal (e.g. 22[+B]) and to the Normally Open auxiliary output 24[O2] ----
programmed for Exit Time signalling. Use the voltage free relay contacts
to power the 230 V lamp.
Telephone line connection
In order to use the telephone communicator options, the telephone line
must be connected to terminals 27 and 28 [LE]. If the telephone line is
shared by another telephone device, it should be connected to terminals
29 and 30 [LI]. In this way the Control panel will give telephone-line priority
to the device connected to terminals [LI], and will switch the line only when
necessary.
ATTENTION To protect the Telecommunication Network and PCB
against surges ----connect the terminal board earth to the Mains earth.
Figure 19 Telephone line connection